Number
Fault phenomenon
Reason for malfunction
Handling measures
Notes
1
The elliptical gear is not turning.
A foreign object has jammed the gears.
Clean and inspect instruments and pipelines, wash or replace filters.
2
Axial seal coupling leakage
Seal packing wear or lack of sealing oil
Tighten the gland or replace the packing, and add sealing oil
3
The pointer rotates unstably
The pointer washer is loose or the rotating parts are not flexible
Re tighten to eliminate inflexibility
4
Excessive negative
measurement error
Bearing wear or deformation or measuring chamber
replace bearings, repair measuring chamber and gears
After repairs,calibration is required.
5
Significant changes in measurement errors
Oil contains gas
Install gas separator
6
Pointers and counters cannot reset to zero
The internal gear of the meter head is damaged or the knob of the meter head is damaged due to collision
Replace the zero return handle,adjust the internal gear or replace the header with a new one